Full scope, one contractor

Services

Every circuit board photographed on this site was wired by our own crew — from first fix through to the signed-off test certificate.

CB-01

Electrical installations

Design through to commissioning — small power, lighting, distribution and everything that carries current between them.

  • Small power and lighting
  • Design
  • Distribution & switchgear
  • Cable management — bus bar trunking, cable tray & conduit
  • Lighting installations and lighting control
  • Emergency lighting design, installation & commissioning
  • External lighting
  • Power installations — sockets, isolators, motor starters
  • Dedicated power supplies & fixed equipment supplies
  • Lightning protection
  • Back-up power — generators, UPS, solar
Custom-built orange distribution board enclosure on site
Technician on a mobile scaffold tower servicing a pole-mounted light

CB-02

Electrical maintenance

Kept running is cheaper than fixed after it fails. We do both.

  • Planned maintenance
  • Reactive maintenance
  • Remedial works
  • Emergency call-outs
  • Minor works — additional sockets or lighting points

CB-03

Electrical testing

Every reading logged with a calibrated meter, not a guess — the same multimeter that shows up in half our site photos.

  • Electrical testing — new installation
  • Electrical — periodic testing
  • Portable appliance testing
  • Emergency lighting scheduled testing
Digital multimeter testing a distribution board
Rooftop solar panel array installed by Alu Power Electric

CB-04

Solar & back-up power

Hybrid inverters and panel arrays sized for the load, wired into the existing distribution board rather than bolted on as an afterthought.

  • Solar system design & installation
  • Hybrid inverter & battery back-up
  • Roof-mount panel arrays
  • Grid-tie and off-grid configurations

Diagnostics

Fault finding

The most common reasons a circuit stops behaving — and where we start looking first.

Loss of supply

Upstream trip, blown fuse or a broken connection before your board.

Earth fault

Current finding a path to earth it shouldn't — tripping RCDs to protect you.

Dead short

Live and neutral meeting directly — instant, high-current trip.

Wrong protective device

A breaker rated for the wrong load, nuisance-tripping or under-protecting.

Defective components

Worn switchgear or terminals failing under normal use.

Control circuit breakdown

The logic driving contactors or starters has failed, not the power itself.

Reversed polarity

Live and neutral swapped somewhere in the run.

Initial faults

Snags on newly installed work, caught during commissioning tests.

Phase rotation

Three-phase motors running the wrong direction from a swapped phase.

Also on the van

Additional services

Security systems

Air-con & refrigeration

Appliance repair

Board upgrades

Electrician on call, 24/7

Plumbing

Not sure which service you need?

Describe the problem and we'll point you at the right fix.

Send an enquiry